– With vector control and auto-tuning function, 200% starting torque at 0.3Hz
– sensorless vector control function for Up/Down control application
– Energy saving function: Automatically adjust the minimum output voltage corresponding to the specified speed
– Function to check rotation direction and frequency, allowing quieter motor start (such as for pump and fan motors)
– During power failure or temporary power outage, the inverter can decelerate and stop the motor in the event of power failure by using braking energy.
– Built-in noise filter
– ModBus-RTU communication allows you to perform network operations at a low cost
Application |
Fans, pumps, HVAC, cranes and lifting machines, conveyor belts, air compressors, extrusion machines, winding machines, machine tools… |
Power supply |
3 phase 200V, 3 phase 400V, (− 15% to +10% ) 50-60Hz (± 5%) |
Wattage |
5.5-55 kW (200 V), 5.5-55 kW (400 V) |
Electric |
24-220 A (200V), 14-112 A (400V) |
Frequency range |
0.1-400Hz |
Starting torque |
150%-200% depending on the control method |
Overload capacity |
150%/60 s, 200%/3 s |
Control method |
Pulse Width Modulation (PWM) |
Brakes |
5.5-22kw: Built-in brake resistor 30-55kw: Must connect external resistor |
Input |
Multifunction input, thermistor input |
Way out |
Multi-function output, monitoring output |
Protection function |
Over-current protection, over-voltage protection, undervoltage protection, electronic thermal protection, temperature fault protection, transient power-off compensation protection, open-phase input protection, brake resistor overload protection, Protection against momentary power failure, power-on earthing overcurrent fault, USP fault, emergency interrupt, CT fault, communication error |
Main function |
Free V/f setting (7), Upper/lower frequency limit, Hopping frequency, Curve acceleration/deceleration, Manual torque increase/decrease, Energy saving operation, Adjustment meter, Start frequency, Carrier frequency adjustment, Electronic thermostat function, (free setting), External start/end (frequency/speed), Analog input selection , Trip retry, Restart during temporary power off, Various signal outputs, Reduced voltage restart, Overload limit, Initial value setting, Auto deceleration at power off , AVR function, dimming acceleration/deceleration, Auto-tuning (Online/Offline), High-torque multi-control (sensor-less vector control of two screens with one Inverter)
|
The media |
RS485 (ModBus-RTU) |
Expansion device |
AC reactor, DC reactor, brake resistor, noise filter, digital cable, regenerative brake unit. |
Protection level |
IP20 |