Recent post
Application |
Normal load: Fan, pump, HVAC Heavy loads: Conveyors, Packing machines, Food processing. cranes and lifting machines, air compressors, extrusion machines, winding machines, machine tools, industrial washing machines… |
Power supply |
3-phase 200 V -15% to 240 V +10%, 50/60 Hz ±5% 3-phase 380 V -15% to 480 V +10%, 50/60 Hz ±5% |
Wattage |
0.4/0.75 - 55/75 kW (3P, 200 VAC), 0.4/0.75 – 132/160 kW (3P, 400 VAC) |
Electric |
3.0/3.7 – 220/270 A (3P, 200 VAC), 1.5/1.9 – 260/290 A (3P, 400 VAC) |
Frequency range |
0.01-400Hz |
Starting torque |
- Sensorless vector control For 0.4 to 55kW: 200%/0.3 Hz (CT), 150%/0.5 Hz (VT) For 75 to 132kW: 180%/0.3 Hz (CT), 120%/0.5 Hz (VT) - 0-Hz sensorless vector control For 0.4 to 55kW: 150%/Torque at 0 Hz (CT), VT no function For 75 to132kW: 130%/Torque at 0 Hz (CT), VT no function |
Overload capacity |
Heavy load rating (CT): 150%/60 s, 200%/3 s (180%/3 s for 75 kW or more) |
Control method |
Phase-to-phase sinusoidal modulation (PWM) |
Brakes |
Inverter 22kW or less with built-in dynamic brake control circuit for quick stop when combined with braking resistor |
Input |
Frequency setting, forward or reverse active/stop, multi-function input, Thermistor input |
Way out |
Multi-function output, Multi-function monitoring terminal |
Protection function |
Over-current, over-voltage, under-voltage protection, electronic thermal protection, temperature fault, Momentary power cut / Power cut off protection, Input phase loss protection, Brake resistor overload protection, Current detection Power-on error, USP error, External trip, Emergency interrupt shutdown, CT error, Communication error, Optional error |
Main function |
Free V/f setting, Upper/lower frequency limit, Hopping frequency, Curve acceleration/deceleration, Manual torque increase/decrease, Energy saving operation, Analog gauge adjustment , Start frequency, Carrier frequency adjustment, Electronic thermostat function (free setting), External start/stop (frequency/scale), Analog input selection, Action retry Program, Restart during temporary power off, Various signal outputs, Reboot voltage drop, Overload limit, Initial value setting, Auto deceleration at power off, AVR function , dimming acceleration/deceleration, Auto tuning (Online/Offline) |
The media |
Supports RS-485, EtherCAT, CompoNet, DeviceNet communication standards |
Expansion device |
Resistor, AC reactor, DC reactor, digital operator, digital operator cable, Noise filter, Regenerative brake unit, etc |
Protection level |
IP20 (0.4 to 55 kW) |
Bridge diagram
Reviews
There are no reviews yet.